返回 产品详情
Hawke S-Series Size2L Enclosure,Hawke不锈钢防爆接线盒
来自上海颐品自动化科技有限公司
¥面议元/
发布时间  2025-12-31 关注次数  59
上海颐品自动化科技有限公司
家家通 3年
图文介绍 产品参数 供应商信息

Hawke S-Series Size2L Enclosure,Hawke不锈钢防爆接线盒
Hawke S-Series Size2L Enclosure,Hawke不锈钢防爆接线盒
上海颐品自动化,:

Hawke S-Series Size2L Enclosure,Hawke不锈钢防爆接线盒
Hawke S-Series Size2L Enclosure,Hawke不锈钢防爆接线盒
上海颐品自动化,:

Hawke S-Series Size2L Enclosure

Increased Safety Exe / Dual Certified ATEX - IECEx

Materials & Finishes

316 L Stainless Steel.

Technical Data

  1. Increased Safety ex logo II 2 GD Exe II ExtD
  2. Size 2L Certificate No's
    Baseefa08ATEX0208X and IECEx BAS 08.0065X.
  3. Z Size 2L Certificate No's
    Baseefa08ATEX0207U and IECEx BAS 08.0064U.
  4. Suitable for use in:
    Zone 1, Zone 2, Zone 21 and Zone 22.
  5. Construction and Test Standards:
    IEC/EN 60079-0, IEC/EN 60079-7, IEC/EN 61241-0 and IEC/EN 61241-1.
  6. Ingress Protection:
    IP66 to IEC/EN 60529.
  7. Deluge Protection to:
    DTS01
  8. Operating Temperature Range:
    -60°C to +80°C
  9. Temperature class & ambient:
    T6 40°C, optional T5 with ambients up to 65°C.
  10. 210mm deep option available.
MAXIMUM QUANTITY OF ENTRIES PER FACE
Thread SizeM16M20/OM20/AM25M32M40M50
Bottom Face C
Quantity
26 #181811654 *
Side Faces B & D
Quantity
11 #885322
# Serrated washers/locknuts with large outside diameters may foul on adjacent cable glands.
* Serrated washers/locknuts must not foul on aperture wall.
TERMINAL CAPACITY DATA
Terminal TypeConductor Size (mm²)Max.
Volts
Max. Physical
Terminal Content
Reduced Terminal Content
At Max. Terminal Amps
Min.Max.Terminal
Quantity
AmpsTerminal
Quantity
Amps
WDU 2.50.52.555011761517
WDU 40.546907591422
WDU 60.5655063121129
WDU 101.51055054171040
WDU 161.5166904224853
WDU 352.5356903040687
WDU 50N6506902453888
WDU 70N107069016165134
WFF 352.5351100676676
The enclosure is supplied with an integral internal/external earth stud assembly.
The terminals listed are restricted to a minimum operating temperature of -50°C.

S-Series & EJB Series Enclosures Technical Inbation

To ensure that the maximum temperature as permitted by certification is not exceeded, the dissipated wattage factor bula is used: W = N x F x I² (see enclosure wattage factor).

It is not permitted to fit more than one conductor per side in rail or direct mounted terminals unless using an insulated Bootlace Ferrule.

Linked and mixed terminal arrangements other than those specified in the data tables are available, but the voltage and current figures may be affected to ensure the maximum certified wattage factor is not exceeded. Please contact Hawke Technical Sales for more inbation.

For Intrinsically Safe Applications, Exe power terminals can be supplied in blue on request. (Note: the enclosure will remain Exe certified).

The enclosure is provided with an integral internal / external earth stud assembly, but when required, one or more rail mounted earth terminals may be fitted inside the enclosure but the quantity of power terminals shall be reduced accordingly. (Note: power terminals may be used as ‘clean earths’).

The enclosure has metric bance / plain entry holes as standard. Alternative bance holes are available provided they are to a recognised standard e.g. BSPP, ET etc. (Parallel threads only). Plain entry holes must maintain the following:
a) The plain hole shall be no larger than 0.7mm above the major diameter of the entry thread.
b) The cable gland or stopping plug is secured internally by a locknut, such that the cable gland or stopping plug will not be dislodged by a 7Nm impact.
c) The enclosure should be maintained at IP66 by the use of a suitable sealing washer under the shoulder of the cable gland.

The customer may drill plain entry holes in the enclosure providing they are in accordance with the relevant code of practice and comply with the certification, contact Hawke Technical Sales for more inbation.

When mixed entries are required on a face, contact Hawke Technical Sales for more inbation.

All unused entry holes must be fitted with a stopping plug as listed on the enclosure certificate. The stopping plug shall be held in place by a locknut.

Specification

S-Series Certification: ex logo II2 GD Exe II ExtD.

EJB Series Certification: Certificate No's Baseefa 08ATEX0208X and IECEx BAS08.0065X.

Zones of Use: Zone 1, Zone 2, Zone 21 & Zone 22.

Temperature Class & Ambients: T6 40°C as standard. Optional T5 with ambients up to 65°C.

Operating Temperature Range: 60°C to +80°C.

Degree of Protection: IP66 and Deluge proof to DTS01.

Material: 316 L Stainless Steel.

Finish: Electropolished as standard (optional - unpolished finish).

Impact Resistance: Up to 7Nm.

Weatherproofing: By bonded silicone sponge lid and gland plate gaskets.

Certification Label: Stainless Steel or optional certified self adhesive foil.

Lid Fixing Screws: Stainless Steel (complete with nylon retaining washer).

Additional Options: Breather/Drain devices. Epoxy paint finish for colour coding. EMI/RFI wire mesh on lid gasket for EMC requirements.

Additional Labels: Stainless Steel or laminated plastic (traffolyte) for external use only or optional (certified) self adhesive foil for external and/or internal use.

Window: Windows available for S2 / ZS2 to S9 / ZS9 Stainless Steel boxes. Windows will be located in the lid and are manufactured from 6mm thick toughened glass with a Stainless Steel Grade 316L frame and silicone sponge gaskets which provide IP66 Ingress Protection.

Internal Mounting Plates: The S / ZS Series boxes can be supplied with an internal plated steel or stainless steel mounting plate.

Earth Continuity

These enclosures have an integral internal / external earth stud assembly.

Enclosures Dissipated Wattage

ENCLOSURE DISSIPATED WATTAGE
Enclosure TypeTemperature Class
T6 40°C & T5 55°CT6 55°CT5 40°CT6 65°CT5 65°C
PL5111.61.02.20.61.2
PL513 GRP4.12.55.61.53.5
PL520 GRP4.836.61.83.6
PL612 GRP4.12.55.61.53
PL615 GRP6.448.82.44.8
PL620 GRP11.47.115.64.28.5
PL626 GRP11.47.115.64.28.5
PL630 GRP20.81328.67.815.6
PL642 GRP20.81328.67.815.6
PL644 GRP20.81328.67.815.6
PL712 GRP3.352.144.61.22.4
PL722 GRP5.313.327.31.93.9
Size 1 Stainless Steel13.958.719.15.210.4
Size 2 Stainless Steel18.1511.324.96.813.6
Size 2L Stainless Steel18.1511.324.96.813.6
Size 3 Stainless Steel23.714.832.58.817.7
Size 4 Stainless Steel29.9518.741.111.222.4
Size 4L Stainless Steel29.9518.741.111.222.4
Size 5 Stainless Steel32.8520.545.112.324.6
Size 6 Stainless Steel4025551530
Size 7 Stainless Steel5223.571.519.539
Size 8 Stainless Steel6540.689.324.348.7
Size 9 Stainless Steel79.3549.5109.129.759.5
EJB14.742.966.511.7783.55
EJB26.644.159.132.494.98

Dissipated Wattage Factor

The Dissipated Wattage Factor of the enclosures has been established by test to ensure that the maximum temperature as permitted by temperature certification is not exceeded. When terminal quantities greater than those at maximum amps are required (up to maximum physical quantity only) then the current shall be reduced accordingly to remain within the Dissipated Wattage Factor of the enclosure.

Combined Terminal Resistance Factor

This factor is used to determine the number of terminals that can be accommodated within the enclosure without exceeding the Wattage Factor. The Combined Terminal Resistance Factor is the sum of the individual terminal resistance's and the resistance of the cable core equal in length to the enclosure maximum diagonal. (Core Resistance is taken from BS6360). Combined terminal resistance factor.

Wattage to be Dissipated = N x F x I²

N = Number of Terminals. F = Combined Terminal Resistance Factor. I = Maximum Current.

e.g. Number of terminals in a PL630 Enclosure at 20.8 Watts - 10 x 'WDU 2.5' (1=17A), 2 x 'WDU 6' (1=29A), (10 x 0.003035 x 17 ² = 8.77 watts) + (2 x 0.001404 x 29 ²) = 2.36 watts). Total Watts = 8.77 + 2.36 = 11.13 watts.

Therefore this terminal combination is acceptable as the wattage is less than that of the PL630 maximum watts of 20.8 watts.

Note - If a smaller than maximum permitted conductor is fitted into a power terminal, then the smaller conductor resistance must be used when calculating the combined terminal resistance.

Transposed Formula

enclosures dissipated wattage equation

S-Series Stainless Steel Enclosures

Combined Terminal Resistance (Ω)
Terminal TypeEnclosure Type
Size 1Size 2Size 2LSize 3Size 4Size 4LSize 5Size 6Size 7Size 8Size 9
WDU 2.5N0.0026350.0035090.0040280.0041760.0046500.005190.0052650.0062290.0073620.0084370.009534
WDU 2.50.0026050.0034790.0039980.0041460.0046200.005170.0052350.0061990.0073320.0084070.009504
WDU 40.0017250.0022690.0025920.0026840.0029790.0033200.0033620.0039610.0046660.0053350.006017
WDU 60.0012260.0015890.0018050.0018660.0020630.0022910.0023190.0027190.0031910.0036370.004093
WDU 100.0007620.0009780.0011060.0011420.0012600.0013940.0014110.0016490.0019290.0021950.002466
WDU 160.0005030.0063900.0007190.0074200.0008160.0009000.0009110.0010610.0012370.0014040.001574
WDU 350.0002610.0003230.0003590.0003700.0004030.0004420.0004470.0005150.0005950.0006710.000749
WDU 50N-0.0002340.0002620.0002690.0002940.0003230.0003260.0003760.0004360.0004920.000549
WDU 70N-0.00017400.0001930.0001980.0002150.0002350.0002370.0002720.0003130.0003520.000392
WDU 70/95----0.0002250.0002450.0002470.0002820.0003230.0003620.000402
WDU 70/95----0.0001820.0001960.0001980.0002230.0002520.0002800.000309
WDU120/150----0.0001590.0001700.0001710.0001910.0002150.0002370.000259
WDU 120/150----0.0001420.0001510.0001520.0001680.0001870.0002050.000224
WFF 35-0.0002630.0002990.0003100.0003430.0003830.0003870.0004550.0005350.0006110.000689
WFF 70----0.0001850.0002050.0002070.0002420.0002830.0003220.000362
WFF 120----0.0001090.000120.0001210.0001410.0001650.0001870.000209
WFF 185-------0.0000980.0001140.0001280.000143
WFF 300-------0.0000680.0000770.0000860.000094

Combined Terminal Resistance

S-Series Stainless Steel Enclosures

Combined Terminal Resistance (Ω)
Terminal TypeEnclosure Type
Size 1Size 2Size 2LSize 3Size 4Size 4LSize 5Size 6Size 7Size 8Size 9
WDU 2.5N0.0026350.0035090.0040280.0041760.0046500.005190.0052650.0062290.0073620.0084370.009534
WDU 2.50.0026050.0034790.0039980.0041460.0046200.005170.0052350.0061990.0073320.0084070.009504
WDU 40.0017250.0022690.0025920.0026840.0029790.0033200.0033620.0039610.0046660.0053350.006017
WDU 60.0012260.0015890.0018050.0018660.0020630.0022910.0023190.0027190.0031910.0036370.004093
WDU 100.0007620.0009780.0011060.0011420.0012600.0013940.0014110.0016490.0019290.0021950.002466
WDU 160.0005030.0063900.0007190.0074200.0008160.0009000.0009110.0010610.0012370.0014040.001574
WDU 350.0002610.0003230.0003590.0003700.0004030.0004420.0004470.0005150.0005950.0006710.000749
WDU 50N-0.0002340.0002620.0002690.0002940.0003230.0003260.0003760.0004360.0004920.000549
WDU 70N-0.00017400.0001930.0001980.0002150.0002350.0002370.0002720.0003130.0003520.000392
WDU 70/95----0.0002250.0002450.0002470.0002820.0003230.0003620.000402
WDU 70/95----0.0001820.0001960.0001980.0002230.0002520.0002800.000309
WDU120/150----0.0001590.0001700.0001710.0001910.0002150.0002370.000259
WDU 120/150----0.0001420.0001510.0001520.0001680.0001870.0002050.000224
WFF 35-0.0002630.0002990.0003100.0003430.0003830.0003870.0004550.0005350.0006110.000689
WFF 70----0.0001850.0002050.0002070.0002420.0002830.0003220.000362
WFF 120----0.0001090.000120.0001210.0001410.0001650.0001870.000209
WFF 185-------0.0000980.0001140.0001280.000143
WFF 300-------0.0000680.0000770.0000860.000094

S-Series Enclosures Maximum Physical Quantity Of Terminals

W Series Terminals

MAXIMUM PHYSICAL QUANTITY OF TERMINALS
Terminal TypeEnclosure Type
SIZE 1SIZE 2SIZE 2LSIZE 3SIZE 4SIZE 4LSIZE 5SIZE 6SIZE 7SIZE 8SIZE 9
WDU 2.530 (1 rail only)78 (2 rails-39 per rail)117 (3 rails - 39 per rail)126 (2 rails-63 per rail)189 (3 rails-63 per rail)252 (4 rails-63 per rail)249 (3 rails-83 per rail)416 (4 rails-104 per rail)640 (5 rails-128 per rail)912 (6 rails-152 per rail)1232 (7 rails-176 per rail)
WDU 425 (1 rail only)50 (2 rails-25 per rail)75 (3 rails - 25 per rail)94 (2 rails-47 per rail)141 (3 rails-47 per rail)188 (4 rails-47 per rail)192 (3 rails-64 per rail)320 (4 rails-80 per rail)515 (5 rails-103 per rail)720 (6 rails-120 per rail)980 (7 rails-140 per rail)
WDU 619 (1 rail only)42 (2 rails-21 per rail)63 (3 rails - 21 per rail)72 (2 rails-36 per rail)108 (3 rails-36 per rail)144 (4 rails-36 per rail)144 (3 rails-48 per rail)240 (4 rails-60 per rail)380 (5 rails-76 per rail)540 (6 rails-90 per rail)735 (7 rails-105 per rail)
WDU 1015 (1 rail only)36 (2 rails-18 per rail)54 (3 rails - 18 per rail)56 (2 rails-28 per rail)84 (3 rails-28 per rail)112 (4 rails-28 per rail)120 (3 rails-40 per rail)200 (4 rails-50 per rail)300 (5 rails-60 per rail)438 (6 rails-73 per rail)595 (7 rails-85 per rail)
WDU 1613 (1 rail only)28 (2 rails-14 per rail)42 (3 rails - 14 per rail)48 (2 rails-24 per rail)72 (3 rails-24 per rail)96 (4 rails-24 per rail)96 (3 rails-32 per rail)160 (4 rails-40 per rail)250 (5 rails-50 per rail)360 (6 rails-60 per rail)490 (7 rails-70 per rail)
WDU 359 (1 rail only)20 (2 rails-10 per rail)30 (3 rails - 10 per rail)36 (2 rails-18 per rail)54 (3 rails-18 per rail)72 (4 rails-18 per rail)72 (3 rails-24 per rail)120 (4 rails-30 per rail)190 (5 rails-38 per rail)270 (6 rails-45 per rail)371 (7 rails-53 per rail)
WDU 50NN/A16 (2 rails - 8 per rail)24 (2 rails - 12 per rail)28 (2 rails - 14 per rail)42 (3 rails - 16 per rail)60 (4 rails - 15 per rail)56 (3 rails - 14 per rail)96 (4 rails - 24 per rail)155 (5 rails - 31 per rail)216 (6 rails - 36 per rail)308 (7 rails - 44 per rail)
WDU 70NN/A8 (1 rail only)16 (2 rails - 8 per rail)14 (1 rail only)30 (2 rails-15 per rail)45 (3 rails-15 per rail)40 (2 rails-20 per rail)50 (2 rails-25 per rail)93 (3 rails-31 per rail)108 (3 rails-36 per rail)172 (4 rails-43 per rail)
WDU 70/95N/AN/AN/AN/A11 (1 rail only)11* (1 rail only)15* (1 rail only)19* (1 rail only)23* (1 rail only)56* (2 rails-28 per rail)64* (2 rails-32 per rail)
WDU 120/150N/AN/AN/AN/A9* (1 rail only)9* (1 rail only)12* (1 rail only)16* (1 rail only)20* (1 rail only)46* (2 rails-23 per rail)54* (2 rails-27 per rail)
WFF 35N/A6 (1 rail only)6* (1 rail only)11 (1 rail only)11 (1 rail only)22* (2 rails)15* (1 rail only)38* (2 rails-19 per rail)46* (2 rails-23 per rail)84* (3 rails-28 per rail)96 *(3 rails-32 per rail)
WFF 70N/AN/AN/AN/A9* (1 rail only)9* (1 rail only)12* (1 rail only)16* (1 rail only)40* (2 rails-20 per rail)46* (2 rails-23 per rail)81* (3 rails-27 per rail)
WFF 120N/AN/AN/AN/A7* (1 rail only)7* (1 rail only)9* (1 rail only)12* (1 rail only)15* (1 rail only)36* (2 rails-18 per rail)42* (2 rails-21 per rail)
WFF 185N/AN/AN/AN/AN/AN/AN/A9* (1 rail only)11* (1 rail only)13* (1 rail only)32* (2 rails-16 per rail)
WFF 300N/AN/AN/AN/AN/AN/AN/A9* (1 rail only)11* (1 rail only)13* (1 rail only)32* (2 rails-16 per rail)
* If earth terminals are required, the quantity should be taken from the maximum physical terminal quantity.

Notes:

Earths: Size 1 to 9: When rail earths are required, the power terminals shall be reduced accordingly. Size 1 to 9: Internal/external earth stud is suitable for conductors up to 75mm². For larger conductors, contact Hawke International

Rails: Size 1 to 9: If ‘WFF’terminals are required with ‘‘W’ partitions, then the box size and / or rail quantity may change due to the large b of these partitions.

Box Size: Size 1 to 9: ‘WFF’ series terminals shall be fitted in 210 deep enclosures.

WDU 50N, WDU 70N, WDU70/95, WDU120/150, and all WFF series terminals are fitted on ‘heavy duty’ rail.

Optional Extras

Z-Series Enclosures

The S-Series, EJB range and GRP range enclosures are all available as empty component certified enclosures, allowing for even greater flexibility in their use. If supplied as component certified only, the customer must obtain final certification after fitting their own equipment. Component approved enclosures are denoted by the inclusion of the prefix "Z" i.e. ZS2, ZPL615.

Optional Lid Windows

All enclosure lids for stainless steel enclosures for sizes 2 to 9 in the S-Series and ZS-Series are available with an optional glass viewing b. The bs are manufactured from 6mm thick toughened glass with a 316L stainless steel frame and silicone sponge gaskets which maintain the IP66 rating.

Bespoke Enclosure Design

Should you require a stainless steel enclosure outside of our standard range of products listed, please contact us to discuss the feasibility of producing an enclosure to your requirements.

Drop-in Mounting Plate

The stainless steel enclosures, sizes 1 through 9, are available with an optional "drop-in" mounting plate, making the installation and termination of cabling and associated termination equipment possible. See enclosure accessories for more details.

Internal Document Pockets

The S-Series and ZS-Series enclosures are available with an optional steel internal document pocket upon request. Please contact us for further details.

 

 

中国区分销商:
上海颐品自动化科技有限公司
Shanghai Epin Automation Co.,Ltd.

Website:www.epinautomation。。com
:sales@epinautomation.com
*:

 

上海颐品自动化科技有限公司
  • 公司类型私营有限责任公司
  • 经营模式生产加工-私营有限责任公司
  • 联系人张凯文
  • 联系手机13818772521
  • 联系固话021-60486851
  • 公司地址上海市金山区山阳镇浦卫公路16393号5幢346室
主营业务
CMP/CCG/Hawke/Eaton防爆格兰,REIKU尼龙软管及接头
上海颐品自动化科技有限公司(EPIN AUTOMATION)是一家集生产,销售,进出口加工为一体的股份制合作企业。公司主要生产加工黄铜镀镍电缆接头和尼龙电缆接头以及附件,金属软管和管接头,尼龙波纹管和管接头,PVC走线槽,ABS和PC电气接线盒,电气控制柜,尼龙扎带,号码管,接线端子,绝缘套管和热缩套管以及橡胶密封件等电工电气配线器材。另外,还代理和分销欧洲进口的知名电气品牌产品,部分产品通过RoHS,CE,UL,CSA,TUV,VDE,ATEX等认证。 公司拥有一支积极进取,技术精良的设计和销售团队,并与国内外多家知名机电生产厂商建立了长期友好的合作关系,销售国内外知名品牌电缆保护产品和其他机电产品。为其产品在中国区的市场推广、技术支持、产品销售、售后跟踪等提供专业周到的服务,为客户节约了大量的生产时间和制造成本。 客户至上,诚信为本,为客户创造价值是我司的经营宗旨,我们将以专业的技术支持,快速的产品供应,完善的售后服务,竭诚为工业自动化、机械制造,电子通信、电力电气、铁路机车,仪器仪表,航空船舶,港口设备,石油石化等领域的客户提供高质量的产品和服务。另外,公司也承接工业自动控制和电气工程项目设计和集成,欢迎新老客户咨询洽谈。 目前,我公司代理和经销的主要电气品牌有以下产品: 1、电缆接头系列:Eaton,Hawke,CMP,Peppers,CCG,OSCG,Wiska,Pflitsch等; 2、尼龙软管系列:Interflex,PMA,REIKU,Flexicon,Adaptaflex,Kopex等; 3、金属软管系列:Anamet,Teaflex,Interflex,Adaptaflex,Anaconda等; 4、PVC线槽系列:SES,KSS,Panduit,Unex,Pflitsch,HAWA等; 5、电气接线盒等:Rittal,Hibox,Fibox,Boxco,E-tan,HAWA等; 6、扎带号码管等:EPIN,AVC,KSS,SES,Panduit,Richco等;
张凯文 电话咨询 立即询价