Hawke防爆连接器Hawke Instrum Ex connector
Hawke防爆连接器Hawke Instrum Ex connector
上海颐品自动化,:
Hawke防爆连接器Hawke Instrum Ex connector
Hawke防爆连接器Hawke Instrum Ex connector
上海颐品自动化,:
Hawke Instrum Ex connector
Hazardous Area Connector
Tamb: -40°C to +60°C.
II2 GD Exdbe IIC Extb IIIC Db T85 IP66, 67 & DTS01 deluge protected.
Overview
This revolutionary design allows the live mate and de-mating of signal and low power in hazardous areas safely and quickly. The Instrum
connector is available in two sizes:
The 4-way and the 9-way options will accept cores ranging between 0.5mm² and 2.5mm² and can operate up to a maximum current of 10A (AC1) at 250V AC and 2.5A (DC1) 60V DC.
The 8-way option, designed predominantly for Ethernet applications, will accept cores ranging between 0.14mm² and 0.37mm² and can carry 1A (AC1) at 60V AC and 0.5A (DC1) 60V DC.
Instrum
connectors include an integral Hawke cable gland for easy termination of both armoured and un-armoured cables.
How it works
The InstrumEx connectors are designed to provide ease of installation and speed of use, whilst providing a flexible safe and reliable b for mating and disconnection of circuits which are energised.
The two mating halves are easily engaged and disengaged by two full turns of the ACME custom engaging thread, during which time the pins and socket are protected by the Exd flameproof protection concept. The outer shell of the connector combined with the integral Hawke cable gland seal ensure that the internal connections are protected to the Exe increased safety protection concept.
Instrum
Connector Dimensions

Technical Data (4 Way / 9 Way)
| TECHNICAL DATA - 4 WAY / 9 WAY | |
|---|---|
| Explosion Protection | |
| Ambient Temperature | -40°C to +60°C |
| Certification | Baseefa 06 ATEX 0061X |
| IECEx BAS06.0018X | |
| Ratings 4 Way / 9 Way | Voltage AC 250V |
| Current AC EN 60947-4-3 10A (AC21) | |
| Current AC EN 60947-4-1 10A (AC1) | |
| Current AC EN 60947-4-1 1A (AC3) | |
| Frequency 50/60 Hz | |
| Power Factor 0.9 | |
| Voltage DC 60V | |
| Current DC EN 60947-4-3 2.5A (DC21) | |
| Current DC EN 60947-4-1 2.5A (DC1) | |
| Current DC EN 60947-4-1 0.5A (DC3) | |
| Fuse Rating 4 Way / 9 ay | 10 amp without thermal protection |
| 20A gL with thermal protection | |
| Maximum No. of make & break operation (EN61984) | On load 150 |
| Off load 500 | |
| IP Rating | IP66, IP67 and DTS01 deluge protected. Note: Caps to be fitted to maintain IP ratings when the connector halves are separated |
| Storage Temperature | -50°C to +70°C |
Technical Data (8 way)
| TECHNICAL DATA - 8 WAY | |
|---|---|
| Explosion Protection | |
| Ambient Temperature | -40°C to +60°C |
| Certification | Baseefa 06 ATEX 0061X |
| IECEx BAS06.0018X | |
| Ratings 8 Way | Voltage AC 60V |
| Current AC EN 60947-4-3 1A (AC21) | |
| Current AC EN 60947-4-1 1A (AC1) | |
| Current AC EN 60947-4-1 0.1A (AC3) | |
| Frequency 50/60 Hz | |
| Power Factor 0.9 | |
| Voltage DC 60V | |
| Current DC EN 60947-4-3 0.5A (DC21) | |
| Current DC EN 60947-4-1 0.5A (DC1) | |
| Current DC EN 60947-4-1 0.1A (DC3) | |
| Fuse Rating 8 Way | 0.5 amp without thermal protection |
| 1A gL with thermal protection | |
| Maximum No. of make & break operation (EN61984) | On load 150 |
| Off load 500 | |
| IP Rating | IP66, IP67 and DTS01 deluge protected. Note: Caps to be fitted to maintain IP ratings when the connector halves are separated |
| Storage Temperature | -50°C to +70°C |
Order Codes
When ordering, select the relevant code from each block as shown in the example below:
Instrum/N-BR1-M-B-P-X-0-4-X-A
Instrum![]() | Select Code | Debion | Example Code |
|---|---|---|---|
| Material | N | Nickel Plated Brass | N |
| S | Stainless Steel | ||
| Connector Style | CP | Connector Plug | BR1 |
| FP | Flange Mounted Connector Plug | ||
| CR | Connector Receptacle | ||
| FR | Flange Mounted Connector Receptacle | ||
| BR1 | Bulkhead Receptacle (Fixed Position 1 Standard) | ||
| BR2 | Bulkhead Receptacle (Fixed Position 2) | ||
| BR3 | Bulkhead Receptacle (Fixed Position 3) | ||
| BR4 | Bulkhead Receptacle (Fixed Position 4) | ||
| BR5 | Bulkhead Receptacle (Fixed Position 5) | ||
| Bulkhead Entry Thread | M | Metric Thread (M20 4/8-way / M32 9-way) | M |
| N | NPT Thread ( ½" for 4/8-way / ¾" 9-way) | ||
| R | NPT Alternative Thread ( ¾" for 4/8-way / 1" 9-way) | ||
| X | N/A (for Connector Plug or Connector Receptacle) | ||
| Cross Sectional Area * Bulkhead Receptacle will always be pre-terminated with 1.5mm² conductors, irrespective of cross sectional area. | A | 4 x 0.5 - 1mm² * | B |
| B | 4 x 1.5 - 2.5mm² * | ||
| C | 8 x 0.14 - 0.37mm² | ||
| D | 9 x 0.5 - 1mm² | ||
| E | 9 x 1.5 - 2.5mm² | ||
| Insert Type ** Note: In all installations the "live" side of the connector must always contain the socket insert. | P | Pin Insert ** | P |
| S | Socket Insert ** | ||
| Outer Sheath Diameter | S | Cable Gland Seal 5.5 - 16mm (4-way/8-way) | X |
| A | Cable Gland Seal 12.5 - 20.5mm (9-way) | ||
| B | Cable Gland Seal 16.9 - 26mm (9-way) | ||
| X | N/A (Bulkhead Receptacle) | ||
| Bulkhead Receptacle Cable Length | 0 | 0.5m (standard) | 0 |
| 1 | 1m | ||
| 2 | 2m | ||
| C | Customer Specified | ||
| X | N/A (for Connector Plug and Receptacle) | ||
| Bulkhead Receptacle Pin Quantities # Bulkheads also include an additional earth lead. | 4 | 4 (pins 1-4 terminated) Std. 4-way BR# | 4 |
| 3 | 3 (pins 1,2 and 3 terminated)# | ||
| 8 | 8 (pins 1-8 terminated) Std. 8-way BR# | ||
| 9 | 9 (pins 1-9 terminated) Std. 9-way BR# | ||
| C | Customer Specified | ||
| RJA | RJ45 Jack fitted, wired to T-568A | ||
| RJB | RJ45 Jack fitted, wired to T-568B | ||
| RJC | Customer Specified | ||
| X | N/A (for Connector Plug and Receptacle) | ||
| Armour Clamp Size ** Note: See Clamping Ring table | R | Alternative Clamping Rings B only | X |
| X | N/A (Bulkhead Receptacle) | ||
| S | Standard Clamping Ring O,A,B | ||
| U | Unarmoured/Copper Braid Clamp (in addition to Clamping Rings) | ||
| Certification | A | ATEX/IECEx/EAC/Inmetro/NEC505 | A |
Find A Connector Modifier
Ordering Inbation
For ordering inbation and codes, please see order codes tab.
Order Codes
When ordering, select the relevant code from each block as shown in the example below:
Instrum/N-BR1-M-B-P-X-0-4-X-A
Instrum![]() | Select Code | Debion | Example Code |
|---|---|---|---|
| Material | N | Nickel Plated Brass | N |
| S | Stainless Steel | ||
| Connector Style | CP | Connector Plug | BR1 |
| FP | Flange Mounted Connector Plug | ||
| CR | Connector Receptacle | ||
| FR | Flange Mounted Connector Receptacle | ||
| BR1 | Bulkhead Receptacle (Fixed Position 1 Standard) | ||
| BR2 | Bulkhead Receptacle (Fixed Position 2) | ||
| BR3 | Bulkhead Receptacle (Fixed Position 3) | ||
| BR4 | Bulkhead Receptacle (Fixed Position 4) | ||
| BR5 | Bulkhead Receptacle (Fixed Position 5) | ||
| Bulkhead Entry Thread | M | Metric Thread (M20 4/8-way / M32 9-way) | M |
| N | NPT Thread ( ½" for 4/8-way / ¾" 9-way) | ||
| R | NPT Alternative Thread ( ¾" for 4/8-way / 1" 9-way) | ||
| X | N/A (for Connector Plug or Connector Receptacle) | ||
| Cross Sectional Area * Bulkhead Receptacle will always be pre-terminated with 1.5mm² conductors, irrespective of cross sectional area. | A | 4 x 0.5 - 1mm² * | B |
| B | 4 x 1.5 - 2.5mm² * | ||
| C | 8 x 0.14 - 0.37mm² | ||
| D | 9 x 0.5 - 1mm² | ||
| E | 9 x 1.5 - 2.5mm² | ||
| Insert Type ** Note: In all installations the "live" side of the connector must always contain the socket insert. | P | Pin Insert ** | P |
| S | Socket Insert ** | ||
| Outer Sheath Diameter | S | Cable Gland Seal 5.5 - 16mm (4-way/8-way) | X |
| A | Cable Gland Seal 12.5 - 20.5mm (9-way) | ||
| B | Cable Gland Seal 16.9 - 26mm (9-way) | ||
| X | N/A (Bulkhead Receptacle) | ||
| Bulkhead Receptacle Cable Length | 0 | 0.5m (standard) | 0 |
| 1 | 1m | ||
| 2 | 2m | ||
| C | Customer Specified | ||
| X | N/A (for Connector Plug and Receptacle) | ||
| Bulkhead Receptacle Pin Quantities # Bulkheads also include an additional earth lead. | 4 | 4 (pins 1-4 terminated) Std. 4-way BR# | 4 |
| 3 | 3 (pins 1,2 and 3 terminated)# | ||
| 8 | 8 (pins 1-8 terminated) Std. 8-way BR# | ||
| 9 | 9 (pins 1-9 terminated) Std. 9-way BR# | ||
| C | Customer Specified | ||
| RJA | RJ45 Jack fitted, wired to T-568A | ||
| RJB | RJ45 Jack fitted, wired to T-568B | ||
| RJC | Customer Specified | ||
| X | N/A (for Connector Plug and Receptacle) | ||
| Armour Clamp Size ** Note: See Clamping Ring table | R | Alternative Clamping Rings B only | X |
| X | N/A (Bulkhead Receptacle) | ||
| S | Standard Clamping Ring O,A,B | ||
| U | Unarmoured/Copper Braid Clamp (in addition to Clamping Rings) | ||
| Certification | A | ATEX/IECEx/EAC/Inmetro/NEC505 | A |
Find A Connector Modifier
Ordering Inbation
For ordering inbation and codes, please see order codes tab.
中国区分销商:
上海颐品自动化科技有限公司
Shanghai Epin Automation Co.,Ltd.
Website:www.epinautomation。。com
:sales@epinautomation.com
*:
- 公司类型私营有限责任公司
- 经营模式生产加工-私营有限责任公司
- 联系人张凯文
- 联系手机13818772521
- 联系固话021-60486851
- 公司地址上海市金山区山阳镇浦卫公路16393号5幢346室
-
SFM明杆式铸铁镶铜方闸门暗杆式铸铁镶铜圆闸门 ¥1200.00 -
蓝牌城市清洁洒水车源头直售洒水车告别差价,安心采购 ¥100000.00 -
ZR-RC-HF4P-2*2.5 铂铑热电偶测温测温信号线 ¥8.90 -
圆钢4130成品交货20CrNi2Mo可热处理精加工 ¥6.00 -
蔚仪金相手自一体切割机iqiege®6100ZH ¥100.00 -
WRE-530 高温热电偶 产品优势结构简单无易损的活动部件 ¥1850.00 -
电缆PTY22-19X1 面议 -
矿用电力电缆MYJV-0.6/1KV-3X4.0+1X2.5 面议 -
建 德二手装载机回收二手压路机收购废旧叉车回收来电谈价 ¥3500.00 -
出口锻件20CrMnTi成品交货35CrMnSi来图定制 ¥6.00 -
SA77-Y3KW-NA34-M4减速机维修KF97DRS80M4 ¥9999.00 -
ZR-KX-HS-FVRP -2*1.5热电偶补偿测温线 WRNK-131 电热原件 ¥9.90 -
WZPK-465 防爆热电阻 测定意义 结构简单无易损的活动部件 ¥1850.00 -
环锻件16MnHIC生产厂家20#来图定制 ¥6.00 -
铸铁镶铜方闸门,镶铜铸铁闸门,方闸门扬禹水工机械有限公司 ¥1200.00


家家通
进入店铺
店铺留言
Connector Dimensions